Revamp of storage tank
Scope
- Tank Maintenance – Revamp of 1 storage tank: jacking, repair of bottom, nozzles, platforms and civil works
Key facts & figures
- Revamp of 1 storage tank according EEMUA 159, PGS 29 and EN 14015
- Removal of old nozzles and insert of plates in tank shell
- New wind girder
- Jacking of tank for the complete renewal of annular ring
- Renovation of tank foundation including installation of a HDPE foil and leak detection system
- Repair of bottom with plate patches and installation of new sump
- Removal of old out of service tank nozzles and installation of new ones
- Piping and supports for cable trays
- Hydrotest
Reference
- 30313